title: Understanding SNMP in a SIEM environment and Monitoring RELIANOID Appliance
description: "## An introduction to SNMP SNMP or Simple Network Management Protocol is an application layer protocol defined by the **IETF** in it’s current amend [RFC 1157](https://www.ietf.org/rfc/rfc1157.txt). SNMP base its data representation in an ASN.1 (presentation layer protocol) modification, defined also…"
url: "https://www.relianoid.com/resources/knowledge-base/howtos/understanding-snmp-in-a-siem-environment-and-monitoring-relianoid-appliance/"
updated: "2024-05-15"
category: "Howto's"
---

# Understanding SNMP in a SIEM environment and Monitoring RELIANOID Appliance

## An introduction to SNMP

SNMP or Simple Network Management Protocol is an application layer protocol defined by the **IETF** in it’s current amend [RFC 1157](https://www.ietf.org/rfc/rfc1157.txt). SNMP base its data representation in an ASN.1 (presentation layer protocol) modification, defined also by the **IETF** in the [RFC 1065](https://tools.ietf.org/html/rfc1065) as SMI (Structure and Identification of Management Information).

SNMP allows two ways of working, synchronous (or polling) and asynchronous. The synchronous mode is the most common way of using SNMP, it works by sending **PDUs** (Protocol Data Units) to managed devices which implements SNMP in the network, those PDU could be for data retrieval (GetRequest) which requires a response from the device (GetResponse) or to set a value in a specific object (SetRequest).

SNMP in asynchronous mode works by the use of **traps**. Traps are unsolicited alert PDUs sent by the managed device to a central trap collector station, those traps are the indicator that a critical event has happened in the monitored device, for example, overheating or too much memory usage and are directed to the UDP port 162.

## MIB – Management Information Base

Each object which could be managed by SNMP are grouped hierarchically and represented in a special file called MIB files, those MIBs are descriptors of groups of managed objects organized by under a tree of OIDs (Object Identifiers) which identifies each object in a unique way.

One of the most common MIB files is defined by the **IETF** in the MIB-II.

## SNMP – Architecture

SNMP defines 3 types of entities in its architecture:

**Network Management Stations**: Execute management applications to control and monitor the network elements.
  **Network elements**: Devices such as a RELIANOID Load Balancer which will be monitored by the network management station.
  **Agents**: Software responsible for executing orders sent by the network management stations, like retrieving the value of a specific OID.

In the following picture, it's shown an example of an usual SNMP architecture in a network:

![](https://www.relianoid.com/wp-content/uploads/2019/01/RELIANOID_SNMP_architecture.webp)

## Configuring SNMP in RELIANOID Appliances

RELIANOID appliances come with an SNMP agent implemented on it allowing the Debian GNU/Linux default OIDs to be polled synchronously by a network management station in order to control the state of the load balancer.

To configure SNMP in RELIANOID appliances, it could be done in an easy way through the web GUI as follows:

**1.** Navigate to the appliance web GUI and go to the section System > Local Services on the sidebar:

![](https://www.relianoid.com/wp-content/uploads/2019/01/relianoid_load_balancer_snmp_configuration_webgui.webp)

**2.** Enable the SNMP checkbox and configure the interface from which the incoming requests will be allowed. It's recommendable to set up here the management interface.

**3.** We can change the listening port and the community name, notice that the such name is required when requesting an OID and should be included in the request.

**4.** The last field is the IP address or subnet from which the service will allow incoming requests.

With this service your application delivery can be monitor in a centralized SIEM platform in order to ensure the right traffic behavior.

Please find below some useful SNMP OIDs in order to monitor properly a load balancer. Note that there are a lot of different OIDs to use, so we recommend to use a tool like snmptranslate in order to translate them to a more understandable name for network managers.

### SNMPv3 Configuration

SNMPv3, or **Simple Network Management Protocol version 3**, represents a significant enhancement in security and functionality over its predecessors. It addresses the vulnerabilities of SNMPv1 and SNMPv2 by providing authentication, encryption, and access control features. SNMPv3 introduces the concept of security models, including User-based Security Model (USM) and View-based Access Control Model (VACM), ensuring that only authorized users can access and manage network devices. Authentication mechanisms such as MD5 and SHA are utilized for data integrity, while encryption methods like **DES** and **AES** ensure confidentiality, making SNMPv3 the preferred choice for secure network management in modern environments.

To configure SNMPv3 in the **snmpd.conf** file, several parameters need to be set. Firstly, authentication and privacy protocols must be specified using the **createUser** directive, including the username, authentication protocol (e.g., **MD5** or **SHA**), authentication passphrase, privacy protocol (e.g., **DES** or **AES**), and privacy passphrase. Access control is managed through the **rouser** directive, defining the authorized users and their access privileges. Additionally, the **com2sec** directive establishes the community-to-security name mapping, linking community strings to security names, while the access directive specifies the access control rules, determining which security names can access which MIB objects. Finally, the **syslocation** and **syscontact** directives can be used to set the system location and contact information for SNMP traps and notifications. Through careful configuration of these parameters, SNMPv3 can be effectively deployed to ensure secure and efficient network management.

In order to successfully apply a SNMPv3 configuration in SNMPd, enable SNMP service in the RELIANOID Load Balancer as explained above and then edit the **/etc/snmp/snmpd.conf** file using the template below and uncomment the **createuser**, **createuser** and **rouser**. If additionally, SNMPv3 traps are required then uncomment the SNMPv3 **trapsess** section.

```
agentAddress udp:0.0.0.0:161
rocommunity public 0.0.0.0/0

trapcommunity public
authtrapenable 1

## ATTENTION: Use this user to access to the trap server, change <SNMPTRAP_USER>, <AUTHPASS> and <PRIVPASS>
#createuser <SNMPTRAP_USER> SHA <AUTHPASS> AES <PRIVPASS>
#iquerysecname <SNMPTRAP_USER>
#rouser <SNMPTRAP_USER>

## SNMPv1 remote trap, uncomment the line below and change <HOST> and <PORT>
#trapsink <HOST> <PORT>

## SNMPv2 remote trap, uncomment the line below and change <HOST> and <PORT>
#trap2sink <HOST>
#trapsess -Ci --clientaddr=<HOST> -v 2c

## SNMPv3: remote trap, uncomment the line below and change <AUTHPASS>, <PRIVPASS> and <HOST>
## Gather the <ENGINEID> for every node with this command:
## ENGINEID=`grep oldEngineID /var/lib/snmp/snmpd.conf | awk -F ' ' '{printf $2}'`
#trapsess -Ci -v 3 -u <SNMPTRAP_USER> -e <ENGINEID> -l authPriv -a SHA -A <AUTHPASS> -x AES -X <PRIVPASS> <HOST>

linkUpDownNotifications yes
defaultMonitors yes

# check processes consuming more than 100 MB of memory
monitor -r 30 -o hrSWRunName "high process memory" hrSWRunPerfMem > 100000
# check if the network traffic is more than 100Mb/s aprox in any interface
monitor -D -r 30 "network traffic" ifInOctets 0 100000000000
# check for disk problems
monitor -o dskPath -r 30 -o dskErrorMsg  "dskTable" dskErrorFlag !=0

includeAllDisks 10%
load 7
```

Finally, restart the snmpd service executing:

```
root@ee-noid-01:~# systemctl restart snmpd.service
```

### Generic MIB-II OIDs

Official MIB files can be found at the path **/usr/share/snmp/mibs/** in the load balancer.

#### memTotalSwap

**OID: 1.3.6.1.4.1.2021.4.3.0**
 **MIB: UCD-SNMP-MIB**
 Total swap space configured for the host in kB.

#### memAvailSwap

**OID: 1.3.6.1.4.1.2021.4.4.0**
 **MIB: UCD-SNMP-MIB**
 Swap space currently available in kB.

#### memTotalReal

**OID: 1.3.6.1.4.1.2021.4.5.0**
 **MIB: UCD-SNMP-MIB**
 Real memory installed on the host in kB.

#### memAvailReal

**OID: 1.3.6.1.4.1.2021.4.6.0**
 **MIB: UCD-SNMP-MIB**
 Real memory available in kB.

#### memTotalFree

**OID: 1.3.6.1.4.1.2021.4.11.0**
 **MIB: UCD-SNMP-MIB**
 Total of free memory in kB.

#### memShared

**OID: 1.3.6.1.4.1.2021.4.13.0**
 **MIB: UCD-SNMP-MIB**
 Total of real or virtual memory allocated for use as shared memory in kB.

#### memBuffer

**OID: 1.3.6.1.4.1.2021.4.14.0**
 **MIB: UCD-SNMP-MIB**
 Total of real or virtual memory allocated for use as memory buffer in kB.

#### memCached

**OID: 1.3.6.1.4.1.2021.4.15.0**
 **MIB: UCD-SNMP-MIB**
 Total of real or virtual memory allocated for use as cache memory in kB.

#### laLoad/1

**OID: 1.3.6.1.4.1.2021.10.1.3.1**
 **MIB: UCD-SNMP-MIB**
 1 minute CPU Load.

#### laLoad/2

**OID: 1.3.6.1.4.1.2021.10.1.3.2**
 **MIB: UCD-SNMP-MIB**
 5 minute CPU Load.

#### laLoad/3

**OID: 1.3.6.1.4.1.2021.10.1.3.3**
 **MIB: UCD-SNMP-MIB**
 15 minute CPU Load.

#### SsCpuSystem

**OID: 1.3.6.1.4.1.2021.11.10.0**
 **MIB: UCD-SNMP-MIB**
 Percentages of system CPU processing system-level time.

#### ssCpuRawSystem

**OID: 1.3.6.1.4.1.2021.11.52.0**
 **MIB: UCD-SNMP-MIB**
 Ticks spent in system-level code.

#### ssCpuIdle

**OID: 1.3.6.1.4.1.2021.11.11.0**
 **MIB: UCD-SNMP-MIB**
 Percentage of processor time in idle state.

#### ssCpuRawIdle

**OID: 1.3.6.1.4.1.2021.11.53.0**
 **MIB: UCD-SNMP-MIB**
 Ticks spent idly per CPU.

#### ifNumber

**OID: 1.3.6.1.2.1.2.1**
 **MIB: IF-MIB**
 Number of interfaces in the system.

#### ifTable

**OID: 1.3.6.1.2.1.2.2**
 **MIB: IF-MIB**
 This OID corresponds with a table in the MIB2. Note that tables are different in their representation than scalar objects. Imagine a table with an OID xTable, with columns Coli and index i, to gain access to the column Col1 and index 1, we should request a **snmpget** for xTable.xEntry.Col1.1, where xEntry has only a conceptual meaning, we can also get all entries of a column Col1 with an **snmpwalk** to xTable.xEntry.Col1 or get the full table with a **snmpwalk** to its OID (xTable.xEntry). Lets what we get as columns:

#### ifDescr

**OID: 1.3.6.1.2.1.2.2.1.2**
 **MIB: IF-MIB**
 Interfaces names.

#### ifType

**OID: 1.3.6.1.2.1.2.2.1.3**
 **MIB: IF-MIB**
 Interfaces type, for example, ethernet.

#### ifMtu

**OID: 1.3.6.1.2.1.2.2.1.4**
 **MIB: IF-MIB**
 Maximum Transfer Unit.

#### ifSpeed

**OID: 1.3.6.1.2.1.2.2.1.5**
 **MIB: IF-MIB**
 Current estimated or nominal bandwidth in b/s.

#### ifPhysAddress

**OID: 1.3.6.1.2.1.2.2.1.6**
 **MIB: IF-MIB**
 Lower protocol layer address, for example, MAC address.

#### ifOperStatus

**OID: 1.3.6.1.2.1.2.2.1.8**
 **MIB: IF-MIB**
 Current status.

#### ifInOctets

**OID: 1.3.6.1.2.1.2.2.1.10**
 **MIB: IF-MIB**
 Number of incoming octets.

#### ifInUcastPkts

**OID: 1.3.6.1.2.1.2.2.1.11**
 **MIB: IF-MIB**
 Number of incoming unicast packets.

#### ifInDiscards

**OID: 1.3.6.1.2.1.2.2.1.13**
 **MIB: IF-MIB**
 Number of inbound packets discarded.

#### ifInErrors

**OID: 1.3.6.1.2.1.2.2.1.14**
 **MIB: IF-MIB**
 Number of inbound packets with errors preventing them to be delivered.

#### ifOutOctets

**OID: 1.3.6.1.2.1.2.2.1.16**
 **MIB: IF-MIB**
 Number of transmitted octets.

#### ifOutUcastPkts

**OID: 1.3.6.1.2.1.2.2.1.17**
 **MIB: IF-MIB**
 Number of transmitted unicast packets.

#### ifOutDiscards

**OID: 1.3.6.1.2.1.2.2.1.19**
 **MIB: IF-MIB**
 Number of transmitted packets discarded.

#### ifOutErrors

**OID: 1.3.6.1.2.1.2.2.1.20**
 **MIB: IF-MIB**
 Number of outgoing packets with errors which couldn't be transmitted.

### RELIANOID ADC Enterprise OIDs

#### noidHostname

**OID: 1.3.6.1.4.1.61269.1.0.1**
 **MIB: RELIANOID-MIB**
 Hostname of the ADC.

#### noidHostIPAddress

**OID: 1.3.6.1.4.1.61269.1.0.2**
 **MIB: RELIANOID-MIB**
 IP Address of the ADC.

#### noidLicenseExpDate

**OID: 1.3.6.1.4.1.61269.1.0.3**
 **MIB: RELIANOID-MIB**
 License Expiration Date.

#### noidIpAddress

**OID: 1.3.6.1.4.1.61269.1.0.4**
 **MIB: RELIANOID-MIB**
 IP Address of the related event.

#### noidInterfaceName

**OID: 1.3.6.1.4.1.61269.1.0.5**
 **MIB: RELIANOID-MIB**
 Interface name of the related event.

#### noidSslExpDate

**OID: 1.3.6.1.4.1.61269.1.0.6**
 **MIB: RELIANOID-MIB**
 Expiration Date for SSL Certificate.

#### noidSslCertName

**OID: 1.3.6.1.4.1.61269.1.0.7**
 **MIB: RELIANOID-MIB**
 SSL Certificate Name of the related event.

#### noidAlarmName

**OID: 1.3.6.1.4.1.61269.1.0.8**
 **MIB: RELIANOID-MIB**
 Name of the alarm raised.

#### noidAlarmSeverity

**OID: 1.3.6.1.4.1.61269.1.0.9**
 **MIB: RELIANOID-MIB**
 Severity of the alarm raised, 1 for critical, 2 for major, 3 for minor, 4 for warning, 5 for clearing trap. The clearing trap is included as Varbind with **noidAlarmClearing**.

#### noidAlarmClearing

**OID: 1.3.6.1.4.1.61269.1.0.10**
 **MIB: RELIANOID-MIB**
 OID of the Trap to be cleared. Included when **noidAlarmSeverity** is 5.

### Generic MIB-II Traps

#### linkDown

**OID: 1.3.6.1.6.3.1.1.5.3**
 **Clearance OID: 1.3.6.1.6.3.1.1.5.4**
 **MIB: IF-MIB**
 A linkDown trap signifies that the SNMP entity, acting in an agent role, has detected that the ifOperStatus object for one of its communication links is about to enter the down state from some other state (but not from the notPresent state). This other state is indicated by the included value of ifOperStatus.

#### linkUp

**OID: 1.3.6.1.6.3.1.1.5.4**
 **MIB: IF-MIB**
 A linkUp trap signifies that the SNMP entity, acting in an agent role, has detected that the ifOperStatus object for one of its communication links left the down state and transitioned into some other state (but not into the notPresent state). This other state is indicated by the included value of ifOperStatus.

#### hrSWRunName

**OID: 1.3.6.1.2.1.25.4.2.1.2**
 **MIB: HOST-RESOURCES-V2-MIB**
 A textual description of this running piece of software, including the manufacturer, revision, and the name by which it is commonly known. If this software was installed locally, this should be the same string as used in the corresponding hrSWInstalledName.

#### mteTriggerRising

**OID: 1.3.6.1.2.1.88.2.0.2**
 **Clearance OID: 1.3.6.1.2.1.88.2.0.3**
 **MIB: DISMAN-EVENT-MIB**
 Notification that the rising threshold was met for triggers with mteTriggerType 'threshold'. The bandwidth of any network interface is above the specified threshold. It should be analyzed if the consumption is legitimate.

#### mteTriggerFalling

**OID: 1.3.6.1.2.1.88.2.0.3**
 **MIB: DISMAN-EVENT-MIB**
 Notification that the falling threshold was met for triggers with mteTriggerType 'threshold'. The bandwidth is normal.

#### dskErrorFlag

**OID: 1.3.6.1.4.1.2021.9.1.100**
 **MIB: UCD-SNMP-MIB**
 Error flag signaling that the disk or partition is under the minimum required space configured for it. The load balancer file system is affected, some administration maintenance required. Check the disk status and open an issue to the Support Portal to be investigated.

#### laNames

**OID: 1.3.6.1.4.1.2021.10.1.3.1**
 **MIB: UCD-SNMP-MIB**
 1 minute Load. The load balancer is overloaded, some processes could be inoperative.

### RELIANOID ADC Enterprise Traps

#### noidLicenseExpiration

**OID: 1.3.6.1.4.1.61269.1.1.1**
 **Clearing OID: 1.3.6.1.4.1.61269.1.1.3**
 **MIB: RELIANOID-MIB**
 The load balancer license is expiring soon. Request the renewal of the support service. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**.

#### noidLicenseInactive

**OID: 1.3.6.1.4.1.61269.1.1.2**
 **Clearing OID: 1.3.6.1.4.1.61269.1.1.3**
 **MIB: RELIANOID-MIB**
 The load balancer license is expired. Request the renewal of the support service. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**.

#### noidLicenseOK

**OID: 1.3.6.1.4.1.61269.1.1.3**
 **MIB: RELIANOID-MIB**
 The load balancer license is ok. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidAlarmClearing**.

#### noidClusterNodeToPrimary

**OID: 1.3.6.1.4.1.61269.1.1.4**
 **Clearing OID: 1.3.6.1.4.1.61269.1.1.5**
 **MIB: RELIANOID-MIB**
 The cluster node has switched to Primary. Check the system logs of the load balancer to analyze the main reason of the switch. In the primary node, this OID will be the clearing event of **clusterNodeToSecondary**. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidAlarmClearing**.

#### noidClusterNodeToSecondary

**OID: 1.3.6.1.4.1.61269.1.1.5**
 **Clearing OID: 1.3.6.1.4.1.61269.1.1.4**
 **MIB: RELIANOID-MIB**
 The cluster node has switched to Secondary. Check the system logs of the load balancer to analyze the main reason of the switch. In the secondary node, this OID will be the clearing event of **clusterNodeToPrimary**. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidAlarmClearing**.

#### noidClusterAlert

**OID: 1.3.6.1.4.1.61269.1.1.6**
 **MIB: RELIANOID-MIB**
 There is an alert related with the cluster. Check the description of the alarm and the system logs to analyze the main reason of the alarm. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**.

#### noidBackendDown

**OID: 1.3.6.1.4.1.61269.1.1.7**
 **Clearing OID: 1.3.6.1.4.1.61269.1.1.8**
 **MIB: RELIANOID-MIB**
 Backend is detected down. Check the alarm description and test the availability of the backend from the load balancer. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidIpAddress**.

#### noidBackendUp

**OID: 1.3.6.1.4.1.61269.1.1.8**
 **MIB: RELIANOID-MIB**
 Backend is detected up. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidIpAddress**, **noidAlarmClearing**.

#### noidInterfaceDown

**OID: 1.3.6.1.4.1.61269.1.1.9**
 **Clearing OID: 1.3.6.1.4.1.61269.1.1.10**
 **MIB: RELIANOID-MIB**
 Interface is detected as down. Check the connectivity of the network interface. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidInterfaceName**.

#### noidInterfaceUp

**OID: 1.3.6.1.4.1.61269.1.1.10**
 **MIB: RELIANOID-MIB**
 Interface is detected as up. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidInterfaceName**, **noidAlarmClearing**.

#### noidUpdateAvailable

**OID: 1.3.6.1.4.1.61269.1.1.11**
 **Clearing OID: 1.3.6.1.4.1.61269.1.1.12**
 **MIB: RELIANOID-MIB**
 Load Balancer updates available. Check the packages to update and prepare the update. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**.

#### noidUpdateOK

**OID: 1.3.6.1.4.1.61269.1.1.12**
 **MIB: RELIANOID-MIB**
 Load Balancer is up to date. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidAlarmClearing**.

#### noidCertSSLExpiration

**OID: 1.3.6.1.4.1.61269.1.1.13**
 **Clearing OID: 1.3.6.1.4.1.61269.1.1.14**
 **MIB: RELIANOID-MIB**
 There is an SSL Certificate imported in the load balancer expired. Renew and import the certificate in the load balancer. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidSslCertName**.

#### noidCertSSLOK

**OID: 1.3.6.1.4.1.61269.1.1.14**
 **MIB: RELIANOID-MIB**
 The SSL Certificates are valid. Varbinds: **noidAlarmName**, **noidAlarmSeverity**, **noidHostname**, **noidAlarmClearing**.

## Backends SNMP monitoring from the load balancer

On the other hand, SNMP is very useful in a load balancer point of view as it could be used to gather backends metrics and use them to change the scheduler behavior or to automate the activation and deactivation of backends. Refer to [this link](https://www.relianoid.com/knowledge-base/enterprise-edition/enterprise-edition-v5-1-administration-guide/v5-1-lslb-farms-update-farm-guardian/#Custom_plugin) to get more information about how to use a custom farm guardian check with SNMP.

## Further application delivery monitoring

There are use cases where it's needed to get specific monitoring values like the farms, backends or clustering statistics and states. To gather these specific values, please follow [this article](https://www.relianoid.com/knowledge-base/enterprise-edition/enterprise-edition-v5-2-administration-guide/v5-2-monitoring-stats-farms/) it can also be done through the [REST api](https://www.relianoid.com/zapidocv3.2/).

## Further monitoring resources

Refer to the articles about how to monitor RELIANOID Appliances with Nagios or Zabbix through the following links:

[https://www.relianoid.com/knowledge-base/howtos/monitoring-relianoid-nagios/](https://www.relianoid.com/knowledge-base/howtos/monitoring-relianoid-nagios/)
 [https://www.relianoid.com/knowledge-base/howtos/monitoring-relianoid-zabbix/](https://www.relianoid.com/knowledge-base/howtos/monitoring-relianoid-zabbix/)

Hope that you find this article useful and that it takes you to the next level of using SNMP to monitor **RELIANOID Appliances**!

## References

UCD-SNMP-MIB [http://www.net-snmp.org/docs/mibs/UCD-SNMP-MIB.txt](http://www.net-snmp.org/docs/mibs/UCD-SNMP-MIB.txt)
 SNMP protocol RFC: [https://tools.ietf.org/html/rfc1157](https://tools.ietf.org/html/rfc1157)
 SIM RFC: [https://tools.ietf.org/html/rfc1065](https://tools.ietf.org/html/rfc1065)
 net-snmp: [http://www.net-snmp.org/wiki/](http://www.net-snmp.org/wiki/)
 Debian wiki snmp: [https://wiki.debian.org/SNMP](https://wiki.debian.org/SNMP)
 UCD-SNMP-MIB: [http://www.net-snmp.org/docs/mibs/UCD-SNMP-MIB.txt](http://www.net-snmp.org/docs/mibs/UCD-SNMP-MIB.txt)

### 📄 Download this document in PDF format